Isotec Catalogue - English - page 6

Load testperformedonpanels ISOTECwidth34,2cm, laidon joistssupportingsec. 5x5cm, permanentdownward loaddue to the roofing tiles
(ca. 45daN/m
2
) at ITC (test report 3675/RP/03of05/11/2003).
Distancebetweensupports - I -
(cm)
60
70
80
90
100
110
120
Thickness
ALLOWABLELOADS
80mm
689
595
515
447
396
358
335
100mm
798
708
628
557
495
442
393
120mm
911
808
715
633
562
502
452
Safety factor
3 (1/3 - tensilestrength)
Arrow
Theallowable loadsshownalwaysmeet the thresholdcondition ƒ ≤ 1/200 - l
CHARACTERISTIC
U.M
VALUE
TESTMETHOD
Density
Kg/m
3
38,0
UNI EN ISO845
Initial Thermal Conductivity
l
mean
, i
W/mK
0,021
UNI EN 12667
DeclaredThermal Conductivity
l
D
(afterponderedageingof 25years)
W/mK
0,024
UNI EN 13165AppendixA - C
Thermal Conductance
U
W/m
2
K
0,30per IT80mm
0,24per IT 100mm
0,20per IT 120mm
u=
l
D
/d
(d= thicknesspanel inm)
DeclaredThermal Resistance
R
D
(afterponderedageingof 25years)
m
2
K/W
3,33per IT80mm
4,17per IT 100mm
5,00per IT 120mm
UNI EN 13165AppendixA - C
Constant temperature
°C
- 50
÷
+100
UNI 9051
Dimensional stability
DS(TH)
class
8
UNI EN 1604
Stress resistance
to 10%deformation
CS(10)
kPa
≥120
UNI EN826
kg/cm
2
≥ 1,22
UNI EN826
Water vapor Resistance
[µ]
//
> 50.000
UNI EN 12086
Long termWater Absorption
WL(T)
%
< 0,6
UNI EN 12087
Specificheat
J/KgK
1100
Calorimetric
Emissionof dangeroussubstances
//
conform
UNI EN 13165AppendixZA
Fire reaction
euroclass
F (PUR)
EN 13501-1
euroclass
D (PIR)
EN13501-1,EN13823,EN11915-2
6
Descendant allowable load
(daN/m
2
) -permanent+variable.
Technical characteristics.
IsotecXLandXLPlusbears theCEmark incompliancewith theEuropeanRegulation305/2011/CE, normsUNI EN 13165:2013andUNI EN 13172:2012.System3
(OrganismcertifiedbyCSIS.p.A. n°0497).
1,2,3,4,5 7,8
Powered by FlippingBook